ATI Q46H Residual Chlorine Monitor

|
Water quality monitor from ATI for dual Chlorine and pH monitoring Measurement Range: 0-2.000ppm, 0-20.00ppm or 0-200.0ppm Free of combined chlorine Reagent-less operation Automatic pH compensation Digital communications options |
Siemens MFC Analyser/Controller

|
Siemens (previously Wallace & Tiernan) analyser/controller offers a broad combination of drinking water analysis and disinfection/chemical control in a single unit |
ATI Q45H Residual Chlorine Monitor

|
Water quality monitor from ATI that measures either Free Chlorine or Combined Chlorine (Chloramines) Measurement Range: 0-2.000ppm or 0-20.00ppm Standard, 0-200.0ppm optional Sensitivity: 0001ppm above 0.020ppm Sensor Type: Polarographic membrane Optional pH Senor for automatic pH correction |
ATI A15/79 Total Chlorine Monitor

|
Total Chlorine monitor from ATI measures total chlorine using standard KI chemistry while measuring released iodine in the gas phase, eliminating sensor fouling problems. Measurement Range: 0-2.000ppm or 0-20.00ppm Sensitivity: ± 0.1% FS Sensor Type: Membraned I2 Gas Sensor |
ATI Q45/79 Total Chlorine Monitor

|
Water quality meter by ATI for continuous online measurement of Total Chlorine. Measurement Range: 0-200 PPB or 0-2.000, 0-20.00 ppm Sensitivity: ± 0.1% of FS Sensor Type: Membraned I2 Sensor |
ATI B20 Residual Chlorine Recorder

|
Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI’s B20 provides an integrated solution to this problem, combining both the analyzer and recorder functions in a single package. This means simpler installation, easier operation, and lower cost. And best of all, the system uses our direct measuring membraned sensor for reliable measurement with minimal maintenance |
Wallace & Tiernan Depolox 3 Plus

|
Wallace & Tiernan (now Siemens) Depolox chlorine monitor measures either Free Chlorine or Combined Chlorine (Chloramines) Measurement Range: 0-0.20, 0-0.50, 0-1.00, 0-2.00, 0-5.00, 0-10.0 and 0-20.0mg/l Sensitivity: 0.01mg/l or 2% FS whichever is greater Sensor Type: Potentiostatic 3 electrode amperormeter, bare electrode or membrane |
Wallace & Tiernan MFP Depolox 4

|
Wallace and Tiernan (now Siemens) Depolox chlorine monitor measures either Free Chlorine or Combined Chlorine (Chloramines) Measurement Range: 0-100, 0-200, 0-500µg/l or 0-1.00, 0-2.00, 0-5.00, 0-10.0, 0-20.0, 0-50.0 & 0-100mg/l Sensitivity: 0.01mg/l or 2% FS whichever is greater Sensor Type: Potentiostatic 3 electrode amperometric, bare electrode or membrane Optional pH package for automatic pH correction. |