ATI Q46H Residual Chlorine Monitor

Water quality monitor from ATI for dual Chlorine and pH monitoring
Measurement Range: 0-2.000ppm, 0-20.00ppm or 0-200.0ppm
Free of combined chlorine
Reagent-less operation
Automatic pH compensation
Digital communications options

 

 



Siemens MFC Analyser/Controller

Siemens (previously Wallace & Tiernan) analyser/controller offers a broad combination of drinking water analysis and disinfection/chemical control in a single unit

 



ATI Q45H Residual Chlorine Monitor

Water quality monitor from ATI that measures either Free Chlorine or Combined Chlorine (Chloramines)
Measurement Range: 0-2.000ppm or 0-20.00ppm Standard, 0-200.0ppm optional
Sensitivity: 0001ppm above 0.020ppm
Sensor Type: Polarographic membrane
Optional pH Senor for automatic pH correction


ATI A15/79 Total Chlorine Monitor

Total Chlorine monitor from ATI measures total chlorine using standard KI chemistry while measuring released iodine in the gas phase, eliminating sensor fouling problems.
Measurement Range: 0-2.000ppm or 0-20.00ppm
Sensitivity: ± 0.1% FS
Sensor Type: Membraned I2 Gas Sensor


 
ATI Q45/79 Total Chlorine Monitor


Water quality meter by ATI for continuous online measurement of Total Chlorine.
Measurement Range: 0-200 PPB or 0-2.000, 0-20.00 ppm
Sensitivity: ± 0.1% of FS
Sensor Type: Membraned I2 Sensor


 


ATI B20 Residual Chlorine Recorder

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI’s B20 provides an integrated solution to this problem, combining both the analyzer and recorder functions in a single package. This means simpler installation, easier operation, and lower cost. And best of all, the system uses our direct measuring membraned sensor for reliable measurement with minimal maintenance


 


 

Wallace & Tiernan Depolox 3 Plus

Wallace & Tiernan (now Siemens) Depolox chlorine monitor measures either Free Chlorine or Combined Chlorine (Chloramines)
Measurement Range: 0-0.20, 0-0.50, 0-1.00, 0-2.00, 0-5.00, 0-10.0 and 0-20.0mg/l
Sensitivity: 0.01mg/l or 2% FS whichever is greater
Sensor Type: Potentiostatic 3 electrode amperormeter, bare electrode or membrane


Wallace & Tiernan MFP Depolox 4

Wallace and Tiernan (now Siemens) Depolox chlorine monitor measures either Free Chlorine or Combined Chlorine (Chloramines)
Measurement Range: 0-100, 0-200, 0-500µg/l or 0-1.00, 0-2.00, 0-5.00, 0-10.0, 0-20.0, 0-50.0 & 0-100mg/l
Sensitivity: 0.01mg/l or 2% FS whichever is greater
Sensor Type: Potentiostatic 3 electrode amperometric, bare electrode or membrane
Optional pH package for automatic pH correction.